- Stock: 8
- Brand: OEM
- Reward Points: 24
- Model: XY-WT01
- Product Code: 6285
- Warranty: няма
The XY‑WT01 digital temperature controller is a versatile thermostat module featuring a clear LED digital display for real‑time temperature monitoring and precise automatic control. Designed for both heating and cooling applications, this controller is suitable for a wide range of industrial, household, and DIY temperature control systems.
Main Features:
Wide operating temperature range: ‑50 °C to 110 °C – suitable for diverse thermal control needs.
LED digital display for easy viewing of current and set temperatures.
Dual mode control: Heating (H) and Cooling (C) – automatically switch controlled devices based on temperature settings.
High precision control (0.1 °C) for stable temperature regulation.
Relay output rated at up to 10 A – effective for medium‑powered loads.
Includes NTC 10K B3950 temperature sensor with approx. 0.5 m waterproof probe for accurate measurement.
Useful functions such as power‑down memory, high‑temperature alarm, auto‑save settings, and status feedback indicators.
Applications:
✔ Heating and cooling regulation in industrial automation
✔ Temperature control for aquariums, incubators, and fermentation chambers
✔ Protective regulation for electrical devices and ventilation systems
✔ DIY automation, home brewing, and greenhouse temperature control
This controller is compact, user‑friendly, and reliable, making it ideal for both professional setups and hobbyist projects.
XY-t01 digital temperature controller high precision digital display temperature controller module refrigeration and heating
Product functions:
1. Heating mode 'H':
When the detection temperature ≤ the set temperature - return difference temperature, the relay is turned on and the heating equipment starts to work;
When the detection temperature is ≥ the set temperature, the relay is disconnected and the heating equipment stops working;
2. Cooling mode 'C':
When the detection temperature is ≥ the set temperature + return difference temperature, the relay is turned on and the refrigeration equipment starts to work;
When the detection temperature is ≤ the set temperature, the relay is disconnected and the refrigeration equipment stops working;
3. High temperature alarm function ala:
When the actual temperature ≥ the alarm temperature, the system starts the audible and visual alarm, disconnects the relay, and any key stops the audible and visual alarm;
4. Delayed start of OPH:
After completing a normal heating or cooling work, the system starts to count T. only when t ≥ OPH, the system can carry out the next round of heating or cooling work;
5. Temperature correction function ofe (- 10.0 ~ 10.0 ℃):
If the system works for a long time, there may be deviation. Through this function, the actual temperature = measured temperature + calibrated value;
6. Remote reading / setting of parameters:
Start temperature, stop temperature, temperature correction and other parameters can be set through UART;
7. Real time temperature reporting:
If the temperature reporting function is enabled, the product will transmit the detected temperature to the terminal through UART at an interval of 1s for data acquisition;
8. Relay enable (default on):
If the relay is enabled, the relay remains disconnected;
9. Restore factory settings:
Press stop and set for more than 3S at the same time to restore the factory setting;
Operating mode / setting temperature / return difference temperature setting:
1. In the operation interface, briefly press the set key to enter the quick setting interface;
2. After entering the quick setting interface, briefly press the set key to switch the parameters to be set (working mode / set temperature / return difference temperature);
3. Use the up down key to modify the parameter value, and support short press / long press;
4. Press and hold set for more than 3S or for 6S without any key operation, exit the quick setting interface and save the parameters;
Alarm temperature / delay start setting / temperature correction:
1. In the operation interface, long press set for more than 3S to enter the parameter setting interface;
2. After entering the parameter setting interface, briefly press the set key to switch the parameters to be set (alarm temperature / delay start setting / temperature correction);
3. Use the up down key to modify the parameter value, and support short press / long press;
4. Press and hold set for more than 3S or for 6S without any key operation, exit the parameter setting interface and save the parameters;
How to turn on the high temperature alarm (off by default):
Enter the parameter setting interface, switch to the alarm parameter ala interface, and turn on or off the high temperature alarm function by short pressing the stop key; If the high temperature alarm function is off, ALA displays' ---- 'as a reminder;
How to turn on delayed start (off by default):
Enter the parameter setting interface, switch to the alarm parameter OPH interface, and turn on or off the high temperature alarm function by short pressing the stop key; If the high temperature alarm function is off, OPH displays' ---- 'as a reminder;
Serial port control (single chip microcomputer TTL level communication)
Communication standard: 9600bps data bit: 8
Stop bit: 1
Check bit: None
Flow control: Non
- Доставка до адрес: €5.00
- Доставка до офис на Еконт: €4.50
- Доставка до офис на Спиди: €3.50
- Доставка до автомат на Спиди: €2.50
- Доставка до BOXNOW: €2.00
- За фиксиран час се добавя €2.00
- Безплатна доставка при поръчка над €100.00
Всички поръчки се изпращат с застраховка и преглед. Моля при получаването на продукта да го прегледате пред куриера за евентуални наранявания при превоза.
Стоката се изпраща до 2 работни дни след направената поръчка. Имате право да върнете стоката в 14 дневен период, като цената на доставката при връщането е за ваша сметка.