- Stock: 5
- Brand: OEM
- Reward Points: 150
- Model: XM-18
- Weight: 0.56kg
- Product Code: 1749-064
Digital Incubator Thermostat with 7 Control Outputs, Automatic Egg Turning, Heating, Humidification and Ventilation
The XM-18 Automatic Egg Incubator Controller is a multifunctional digital control system designed to automatically monitor and regulate temperature, humidity, ventilation and egg turning during the incubation process. It combines precision temperature and humidity sensors, programmable operating cycles and seven control outputs in one compact control unit.
The controller operates with a mains power supply of AC 160–240V / 50Hz, making it compatible with standard 230V electrical systems in Europe. Its microprocessor-based control system processes sensor readings and automatically manages the connected equipment according to the selected operating parameters.
The unit is equipped with a temperature sensor and a capacitive humidity probe. Temperature is measured over a range of 0–99°C with an accuracy of ±0.1°C, while relative humidity is measured from 0 to 99% RH with an accuracy of ±3% RH. Four digital LED display sections provide convenient monitoring of operating conditions and incubation parameters.
One of the main advantages of the XM-18 is its automatic egg-turning function. The interval between turning cycles can be adjusted from 0 to 999 minutes, while the duration of each turning operation can be set from 0 to 999 seconds. The factory settings are 90 minutes between cycles and 180 seconds for each turning operation. The controller alternates between left and right turning directions and records up to 999 turning cycles.
In addition to temperature and humidity regulation, the module controls periodic air exchange inside the incubator. The ventilation interval is adjustable from 0 to 999 minutes, and the fan operating duration can be set from 0 to 999 seconds. The factory settings are 120 minutes between ventilation cycles and 30 seconds of fan operation.
The seven control outputs manage the main heating system, backup heating, over-temperature protection, left and right egg-turning mechanisms, humidity control and alarm signalling. This allows the controller to automate the essential functions of an egg incubator.
Thanks to its microprocessor-based operation, automatic working cycles and adjustable parameters, the XM-18 is suitable for home incubators as well as small and medium-sized hatcheries.
Key Features:
Fully automated incubation control.
Four digital LED display sections.
Simultaneous temperature and humidity monitoring.
Temperature measurement accuracy of ±0.1°C.
Humidity measurement accuracy of ±3% RH.
Two separate external sensors with connecting cables.
Seven control outputs for peripheral equipment.
Automatic egg turning in alternating left and right directions.
Adjustable egg-turning interval and duration.
Automatic ventilation control.
Main and backup heating management.
Humidity regulation through an external humidifier.
Alarm function for temperature and humidity limits.
Factory-programmed settings for standard incubation operation.
Suitable for home and small commercial incubators.
Control Outputs and Functions:
The controller provides seven signal/control outputs for the following functions:
Temperature Control – Main Heating: Controls the primary heating element according to the selected temperature. Maximum load: 8A / AC 220V.
Insufficient Temperature – Backup Heating: Activates additional heating when the temperature becomes critically low. Maximum load: 8A / AC 220V.
Over-temperature Protection: Output for controlling cooling or excess heat removal. Maximum load: 1A / AC 220V.
Egg Left-turning: Controls the egg-turning mechanism in one direction. Maximum load: 1A / AC 220V.
Egg Right-turning: Controls the egg-turning mechanism in the opposite direction. Maximum load: 1A / AC 220V.
Humidity Control: Controls an external humidifier. Maximum load: 1A / AC 220V.
Alarm: Controls the alarm function when preset critical conditions are reached. Maximum load: 1A / AC 220V.
These load ratings apply to the standard XM-18 version. The seven outputs should not be treated as seven identical high-power switching channels.
Automatic Incubation Cycles:
Egg-turning interval: 0–999 minutes.
Egg-turning duration: 0–999 seconds.
Factory egg-turning interval: 90 minutes.
Factory egg-turning duration: 180 seconds.
Egg-turning counter: Up to 999 cycles.
Ventilation interval: 0–999 minutes.
Ventilation duration: 0–999 seconds.
Factory ventilation interval: 120 minutes.
Factory ventilation duration: 30 seconds.
Automatic alternating egg-turning direction: Left / Right.
Technical Specifications:
Model: XM-18
Type: Automatic Digital Egg Incubator Controller
Operating Voltage: AC 160–240V
Frequency: 50Hz
Power Consumption: Less than 5W (according to supplied specifications)
Temperature Measuring Range: 0–99°C
Temperature Accuracy: ±0.1°C
Humidity Measuring Range: 0–99% RH
Humidity Accuracy: ±3% RH
Temperature Sensor: Digital temperature probe / NTC depending on version
Humidity Sensor: Capacitive humidity probe
Sensor Cable Length: Approximately 1.5–2m
Number of Digital Displays: 4
Number of Control Outputs: 7
Maximum Main and Backup Heater Load: 8A / AC 220V per output
Maximum Load of Other Outputs: 1A / AC 220V per output
Maximum Egg-Turning Records: 999
Adjustable Egg-Turning Interval: 0–999 minutes
Adjustable Egg-Turning Duration: 0–999 seconds
Adjustable Ventilation Interval: 0–999 minutes
Adjustable Ventilation Duration: 0–999 seconds
Dimensions: Approximately 160 × 90 × 80mm
Weight: Approximately 700–800g
Operating Ambient Temperature: -10°C to +60°C
Maximum Ambient Relative Humidity: Less than 85% RH
Factory Settings:
Temperature: 38.0°C
Relative Humidity: 60% RH
Egg-Turning Interval: 90 minutes
Egg-Turning Duration: 180 seconds
Ventilation Interval: 120 minutes
Ventilation Duration: 30 seconds
Egg-Turning Mode: Automatic.
Important Installation and Operating Information:
The controller operates with potentially dangerous AC 160–240V mains voltage. Electrical connections must be performed by a qualified person in accordance with applicable electrical safety requirements.
The main and backup heaters can be connected to their respective outputs with a maximum load of 8A per channel. The remaining functions are limited to 1A per channel. Use suitable external contactors or power relays when controlling higher-power equipment.
Position the sensors correctly inside the incubator and avoid direct contact with water. Dust accumulation and condensation may affect measurement accuracy.
When the power supply is interrupted, the egg-turning counter may reset. Do not rely on it as an independent memory of the complete incubation history.
Check the correct wiring of the turning motor, heaters, humidifier and ventilation fan before starting automatic operation.
Note: The XM-18 is available in different versions with variations in display and output configurations. The seven control outputs and their load ratings described above apply to the standard XM-18 version, not to XM-18S, XM-18SE or other modifications.
- Доставка до адрес: €6.00
- Доставка до офис на Еконт: €5.00
- Доставка до офис на Спиди: €4.00
- Доставка до автомат на Спиди: €3.00
- Доставка до BOXNOW: €2.00
- За фиксиран час се добавя €2.00
- Безплатна доставка при поръчка над €99.00
Всички поръчки се изпращат с застраховка и преглед. Моля при получаването на продукта да го прегледате пред куриера за евентуални наранявания при превоза.