- Stock: 1
- Brand: OEM
- Reward Points: 4
- Model: 4106-30
24H Timing Control Trigger Cycle Timer Delay Switch 12V 24V Relay Switch Module
Wide voltage power supply 5.0v-60v;
One mode can set multiple time periods, up to five time periods;
Alarm function with buzzer.
Function mode introduction:
Ope: closing time of relay; cle: opening time of relay
Time period: PE-1 to PE-5, 5 time periods
"---": function shielding
P-1: Daily ope relay close / output pulse, cle relay open / output pulse
P-2: close / output pulse of ope relay and open / output pulse of CLE relay on the same day
P-3: what day of the month: ope relay close / output pulse, cle relay open / output pulse
P-4: from the day of the month to the day of the month, when does the day start and end: the ope relay closes / the output pulse, the CLE relay opens / outputs the pulse
P-5: from what day of the month to what time of the day does it start and end: ope relay close / output pulse cle relay open / output pulse
Note: stop time / date (CLE) > start time / date (OPE)
1, How to set the time
In the time running interface, press and hold down:
1. The system will enter the time setting interface after "year" is flashing. At this time, the last two digits of "year" will flash, which can be adjusted by down and up (support long press);
2. Press set for a short time, the system will display "DAE" and enter the "month / day" setting interface. At this time, the "month" will not stop flashing, and it can be adjusted by down and up (long press is supported);
3. Press set for a short time, and the "day" will flash. Adjust it through down and up (long press is supported);
4. Press set for a short time, the system will flash "Hou" and enter the "hour / minute" setting interface. At this time, the "time" will not stop flashing, and it can be adjusted by down and up (long press is supported);
5. Press set for a short time. At this time, "Min" will flash. Adjust by down and up (support long press). At this time, press set briefly and repeat step 1;
6. After long press set to release, the time will be modified according to the set parameters and exit the time setting interface;
2, How to set parameters
In the time operation interface, press and hold the set key for 2 seconds, then release the hand, and the system will enter the parameter setting interface
Step 1: select time period: PE-1 ~ PE-5 can be selected by short pressing up and down keys;
Step 2: select the mode: --- "P-1 ~ P-5 (that is, the time period is set to the corresponding mode) by short pressing the up and down keys; (" - "means to block this time period)
Note:
The repetition mode of each time period can be selected from "----", P-1 ~ P-5; for example, five time periods can be allowed to work in P-1 mode at the same time, or time period 1 can work in P-1 mode, and time period 2 can work in P-2 mode; it is very convenient and flexible, and can be combined arbitrarily according to your own needs;
Step 3: after mode selection, short press set to enter the time segment setting interface. In the time segment setting interface, press set to switch parameters, "ope" start time point, "cle" end time point, "DAE" date information;
Step 4: exit the setting after parameter setting, press set key for 2 seconds and then release it to detect whether the parameter setting is legal. If it is legal, save the parameter and return to the time running interface. If the parameter is wrong, "err" will be displayed (stop time / date < = start time / date, error will be reported) and return to the parameter setting interface again;
Note: stop time / date (CLE) > start time / date (OPE)
Additional function: any time period can be set separately
In the specific parameter setting interface (after the second step), short press stop to switch the output mode:
Out1: start point on relay, end point off relay
Out2: output 1s pulse at time point
In the specific parameter setting interface (after the second step), long press stop to switch the ring mode:
Bll0: Ring forbidden
Bll1: Ring enable
Note: after ringing, press any key to stop the ringing
Stop button function extension:
Relay enable mode:
1. On: the relay is on within the conduction time of the relay;
2. Off: the relay is forbidden to conduct and is always closed;
Press the stop button in the time display interface to switch between on and off. The current status will flash and return to the main interface. (this function is an emergency stop function, one key to open the closed relay)
After the relay is forbidden to turn on, the alarm clock function is set after setting the mode.
Sleep mode:
1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, and the program runs normally;
2. O-D normal mode: the nixie tube is always on display;